fix(server): COALESCE diagnostic columns so v1.0 heartbeats don't clear v1.1 data
store_heartbeat_diagnostics() unconditionally SET each diagnostic column to its parameter, so a v1.0.0 heartbeat (which omits the five v1.1.0 fields and leaves them as None after Pydantic parsing) erased previously stored diagnostics for that device. Wrap each parameter in COALESCE(?, column_name) so omitted fields preserve the existing value. Found via adversarial review (gpt-5.5 reviewer, run 2026-05-01-191359). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -70,13 +70,15 @@ def store_heartbeat_diagnostics(
|
||||
else None
|
||||
)
|
||||
cursor = db.cursor()
|
||||
# COALESCE preserves existing column values when the v1.0.0 payload omits
|
||||
# diagnostic fields (Pydantic resolves them to None).
|
||||
cursor.execute(
|
||||
"""UPDATE heartbeats
|
||||
SET reset_reason = ?,
|
||||
heap_free = ?,
|
||||
heap_min_free = ?,
|
||||
last_disconnect_code = ?,
|
||||
recent_events = ?
|
||||
SET reset_reason = COALESCE(?, reset_reason),
|
||||
heap_free = COALESCE(?, heap_free),
|
||||
heap_min_free = COALESCE(?, heap_min_free),
|
||||
last_disconnect_code = COALESCE(?, last_disconnect_code),
|
||||
recent_events = COALESCE(?, recent_events)
|
||||
WHERE device_id = ?""",
|
||||
(
|
||||
hb.reset_reason,
|
||||
|
||||
Reference in New Issue